BJO

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Eter, N
Right arrow Articles by Göbbels, M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Eter, N
Right arrow Articles by Göbbels, M
British Journal of Ophthalmology 2002;86:616-619
© 2002 British Journal of Ophthalmology


SCIENTIFIC CORRESPONDENCE

A new technique for tear film fluorophotometry

N Eter, M Göbbels

Department of Ophthalmology, University of Bonn Medical Center, Bonn, Germany

Correspondence to:
Correspondence to:
Nicole Eter, MD, Department of Ophthalmology, University of Bonn Medical Center, Sigmund-Freud-Strasse 25, D-53105 Bonn, Germany;
eter{at}uni-bonn.de


ABSTRACT
Aim: To develop a reliable and objective non-touch technique for determination of tear volume and tear secretion by means of tear film fluorophotometry.

Methods: 10 defined concentrations of sodium fluorescein were given in an artificial chamber and measured by the Fluorotron Master (Coherent Radiation Inc). A calibration line was established and the calibration equation was programmed into the Fluorotron Master computer software. In 28 patients (56 eyes) with dry eye symptoms and 15 volunteers (30 eyes) tear volume and tear secretion were then measured directly without taking a tear sample, using the new technique.

Results: The values obtained by the Fluorotron Master measuring 10 defined fluorescein concentrations within an artificial chamber are approximately 100 times lower than the actual concentrations. The calibration line led to a calibration equation: y = 36 + 0.01 x X. The mean tear secretion in 56 eyes of patients with dry eye symptoms was 2.48 µl/min, compared to 3.4 µl/min in healthy volunteers. The difference was statistically significant. Average tear volume was 7.0 µl in patients and 7.2 µl in healthy volunteers with no statistically significant difference.

Conclusion: The method developed is a simple and reliable non-touch technique without the need for taking a tear sample, which makes the examination faster and more comfortable for the patient.


Keywords: fluorophotometry; tear film; tear volume; tear secretion




This article has been cited by other articles:


Home page
Br. J. Ophthalmol.Home page
V A Smith, D Khan-Lim, L Anderson, S D Cook, and A D Dick
Does orally administered doxycycline reach the tear film?
Br. J. Ophthalmol., June 1, 2008; 92(6): 856 - 859.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
J D Aronowicz, W E Shine, D Oral, J M Vargas, and J P McCulley
Short term oral minocycline treatment of meibomianitis
Br. J. Ophthalmol., July 1, 2006; 90(7): 856 - 860.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2002 by the BMJ Publishing Group Ltd.