BJO

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Holló, G
Right arrow Articles by Süveges, I
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Holló, G
Right arrow Articles by Süveges, I
British Journal of Ophthalmology 2003;87:1241-1246
© 2003 BMJ Publishing Group Ltd


EXTENDED REPORT

Influence of LASIK on scanning laser polarimetric measurement of the retinal nerve fibre layer with fixed angle and customised corneal polarisation compensation

G Holló1, A Katsanos1, P Kóthy1, A Kerek2, I Süveges1

1 1st Department of Ophthalmology, Semmelweis University, Budapest, Hungary
2 Optimum Private Laser Eye Institute, Budapest, Hungary

Correspondence to:
Correspondence to:
Gábor Holló MD, 1st Department of Ophthalmology, Semmelweis University, H-1083, Budapest, Tömö u, 25–29, Hungary;
hg{at}szem1.sote.hu

Background/aim: Retinal nerve fibre layer thickness (RNFLT), as measured with scanning laser polarimetry using the fixed angle corneal polarisation compensator (SLP-F), has been found to be reduced after uncomplicated laser assisted in situ keratomileusis (LASIK) compared to the pre-LASIK measurement. Since this virtual RNFLT thinning is attributed to the corneal changes induced by the LASIK, the authors investigated whether customised corneal polarisation compensation (SLP-C), which compensates for the actual corneal polarisation during each measurement, can avoid the LASIK induced, virtual changes of the polarimetric RNFLT values.

Methods: Scanning laser polarimetry using both the SLP-F and SLP-C methods (GDx-Access, software version 5.0) was performed on 15 consecutive healthy subjects with no eye disease who underwent LASIK for ametropia correction. The SLP measurements were performed before the surgery, then on day 1 and day 6 after LASIK. Thickness data from images of one randomly selected eye per subject were analysed using the ANOVA and Scheffe multiple comparison tests.

Results: Superior maximum, inferior maximum, normalised superior area, and normalised inferior area (SLP parameters representing the RNFLT at the superior and inferior poles of the optic nerve head) remained unchanged with SLP-C (ANOVA, p>0.05) but decreased (superior maximum, normalised superior area, Scheffe test, p<0.05) or tended to decrease (inferior maximum) after LASIK, when measured using SLP-F. In contrast, certain other parameters—namely, superior ratio and inferior ratio (representing the ratios between the superior or the inferior sector and the temporal sector), maximal modulation, and ellipse modulation decreased with SLP-C (Scheffe test, p<0.05), but remained stable with SLP-F (ANOVA, p>0.05) after LASIK. Superior to nasal ratio, symmetry of the superior and inferior RNFLT as well as the parameter showing the probability of having glaucoma (called "the number") remained unchanged with both types of corneal compensation (ANOVA, p>0.05). With SLP-C the parameter ellipse average thickness increased after LASIK (Scheffe test, p = 0.021). No parameter value altered between day 1 and day 6 after LASIK, for either method.

Conclusion: The results suggest that the LASIK induced decrease of the polarimetric RNFLT, which is consistently detected with polarimeters when using the fixed angle corneal polarisation compensator, is due to alterations of the corneal polarisation. The use of customised corneal polarisation compensation avoids this virtual decrease of the polarimetric RNFLTHowever, our results suggestan increase of the measured retardation in the temporal quadrant of the SLP-C image after LASIK. Since ratios of parameters using the temporal RNFLT in the denominator are important in the polarimetric glaucoma diagnosis algorithm, their decrease as a consequence of using SLP-C needs further investigation.


Keywords: corneal compensator; LASIK; retinal nerve fibre layer thickness; scanning laser polarimetry




This article has been cited by other articles:


Home page
Br. J. Ophthalmol.Home page
M Centofanti, F Oddone, M Parravano, L Gualdi, M G Bucci, and G Manni
Corneal birefringence changes after laser assisted in situ keratomileusis and their influence on retinal nerve fibre layer thickness measurement by means of scanning laser polarimetry
Br. J. Ophthalmol., June 1, 2005; 89(6): 689 - 693.