BJO

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hunt, O A
Right arrow Articles by Gilmartin, B
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hunt, O A
Right arrow Articles by Gilmartin, B
British Journal of Ophthalmology 2003;87:1504-1508
© 2003 BMJ Publishing Group Ltd


EXTENDED REPORT

Evaluation of the measurement of refractive error by the PowerRefractor: a remote, continuous and binocular measurement system of oculomotor function

O A Hunt, J S Wolffsohn, B Gilmartin

Neurosciences Research Institute, School of Life and Health Sciences, Aston University, Birmingham, UK

Correspondence to:
Correspondence to:
Dr J S Wolffsohn
School of Life and Health Sciences, Optometry, Aston University, Aston Triangle, Birmingham B4 7ET, UK; j.s.w.wolffsohn{at}aston.ac.uk

Background/aim: The technique of photoretinoscopy is unique in being able to measure the dynamics of the oculomotor system (ocular accommodation, vergence, and pupil size) remotely (working distance typically 1 metre) and objectively in both eyes simultaneously. The aim of this study was to evaluate clinically the measurement of refractive error by a recent commercial photoretinoscopic device, the PowerRefractor (PlusOptiX, Germany).

Method: The validity and repeatability of the PowerRefractor was compared to: subjective (non-cycloplegic) refraction on 100 adult subjects (mean age 23.8 (SD 5.7) years) and objective autorefraction (Shin-Nippon SRW-5000, Japan) on 150 subjects (20.1 (4.2) years). Repeatability was assessed by examining the differences between autorefractor readings taken from each eye and by re-measuring the objective prescription of 100 eyes at a subsequent session.

Results: On average the PowerRefractor prescription was not significantly different from the subjective refraction, although quite variable (difference +0.05 (0.63) D, p = 0.41) and more negative than the SRW-5000 prescription (by -0.20 (0.72) D, p<0.001). There was no significant bias in the accuracy of the instrument with regard to the type or magnitude of refractive error. The PowerRefractor was found to be repeatable over the prescription range of -8.75D to +4.00D (mean spherical equivalent) examined.

Conclusion: The PowerRefractor is a useful objective screening instrument and because of its remote and rapid measurement of both eyes simultaneously is able to assess the oculomotor response in a variety of unrestricted viewing conditions and patient types.


Keywords: autorefractor; photoretinoscopy




This article has been cited by other articles:


Home page
IOVSHome page
G. M. Tondel and T. R. Candy
Human Infants' Accommodation Responses to Dynamic Stimuli
Invest. Ophthalmol. Vis. Sci., February 1, 2007; 48(2): 949 - 956.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
J. S. Wolffsohn, O. A. Hunt, S. Naroo, B. Gilmartin, S. Shah, I. A. Cunliffe, M. T. Benson, and S. Mantry
Objective Accommodative Amplitude and Dynamics with the 1CU Accommodative Intraocular Lens.
Invest. Ophthalmol. Vis. Sci., March 1, 2006; 47(3): 1230 - 1235.
[Abstract] [Full Text] [PDF]


Home page
IOVSHome page
S. Kasthurirangan and A. Glasser
Influence of Amplitude and Starting Point on Accommodative Dynamics in Humans
Invest. Ophthalmol. Vis. Sci., September 1, 2005; 46(9): 3463 - 3472.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2003 by the BMJ Publishing Group Ltd.