BJO

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jonas, J B
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jonas, J B
British Journal of Ophthalmology 2003;87:577-579
© 2003 BMJ Publishing Group


SCIENTIFIC CORRESPONDENCE

Reproducibility of ophthalmodynamometric measurements of central retinal artery and vein collapse pressure

J B Jonas

Department of Ophthalmology, Faculty of Clinical Medicine Mannheim, University of Heidelberg, Mannheim, Germany

Correspondence to:
Correspondence to:
Dr J Jonas, Universitäts-Augenklinik, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany;
Jost.Jonas{at}augen.ma.uni-heidelberg.de


ABSTRACT
Background: To assess the reproducibility of ophthalmodynamometric measurements using a new, Goldmann contact lens associated, device allowing biomicroscopic visualisation of the optic disc.

Methods: The prospective clinical study included 87 eyes of 58 subjects presenting with a normal fundus (n=40), or ocular diseases (n=47). With topical anaesthesia, a Goldmann contact lens, fitted with a pressure sensor mounted into the holding ring of the contact lens, was placed onto the cornea. Pressure was applied onto the globe through the contact lens, and the pressure values obtained when the central retinal vessels started pulsating were noted. The measurements were performed 10 times.

Results: The mean coefficients of variation for redeterminations of the collapse pressure of the central retinal vein and artery were 16.3% (SD 11.4%), and 8.5% (4.1%), respectively.

Conclusions: A simple and new, Goldmann contact lens associated, ophthalmodynamometer allows central retinal artery and vein collapse pressure measurements which are reproducible in a clinical setting.


Keywords: ophthalmodynamometry; central retinal vein collapse pressure; central retinal artery collapse pressure; intraocular pressure




This article has been cited by other articles:


Home page
IOVSHome page
W. H. Morgan, C. Balaratnasingam, M. L. Hazelton, P. H. House, S. J. Cringle, and D.-Y. Yu
The Force Required to Induce Hemivein Pulsation Is Associated with the Site of Maximum Field Loss in Glaucoma
Invest. Ophthalmol. Vis. Sci., April 1, 2005; 46(4): 1307 - 1312.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
J B Jonas
Ophthalmodynamometric determination of the central retinal vessel collapse pressure correlated with systemic blood pressure
Br. J. Ophthalmol., April 1, 2004; 88(4): 501 - 504.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
J B Jonas
Retinal arterial collapse pressure in eyes with retinal arterial occlusive diseases
Br. J. Ophthalmol., April 1, 2004; 88(4): 589 - 589.
[Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
Y C A Robert
A new look at ophthalmodynamometry
Br. J. Ophthalmol., January 1, 2004; 88(1): 156 - 156.
[Full Text]


Home page
Br. J. Ophthalmol.Home page
J B Jonas
Central retinal artery and vein collapse pressure in eyes with chronic open angle glaucoma
Br. J. Ophthalmol., August 1, 2003; 87(8): 949 - 951.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2003 by the BMJ Publishing Group Ltd.