BJO

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

British Journal of Ophthalmology 2005;89:1298-1301; doi:10.1136/bjo.2005.070649
Copyright © 2005 by the BMJ Publishing Group Ltd.

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Susanna, R
Right arrow Articles by Hatanaka, M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Susanna, R, Jr
Right arrow Articles by Hatanaka, M

EXTENDED REPORT

The relation between intraocular pressure peak in the water drinking test and visual field progression in glaucoma

R Susanna, Jr, R M Vessani, L Sakata, L C Zacarias, M Hatanaka

Glaucoma Service, Ophthalmology Department, University of São Paulo, Brazil

Correspondence to:
Correspondence to:
Dr R M Vessani
Rua Itambé 422, apt 52, São Paulo, São Paulo, Brazil; robves{at}terra.com.br

Aim: To compare the results of the water drinking test between glaucomatous eyes with and without visual field progression.

Methods: Retrospective analysis of 76 eyes of 76 open angle glaucoma patients followed for a mean period of 26.0 (SD 13.8) months. Patients were submitted to the water drinking test at the beginning of the follow up period. Reliable achromatic automated perimetry tests performed during the studied period were used to characterise visual field progression. All subjects were under clinical therapy and had an intraocular pressure (IOP) lower than 17 mm Hg monitored by isolated measurements during the follow up period. The results of the water drinking test were compared between glaucomatous eyes with and without visual field progression.

Results: Twenty eight eyes reached definite visual field progression. There were no significant differences in the mean age, sex, race, basal IOP, number of antiglaucomatous drugs, initial mean deviation (MD), and corrected pattern standard deviation (CPSD) between eyes that showed visual field progression and the ones who did not progress. A significant difference of 1.9 (SD 0.6) mm Hg (p = 0.001, analysis of covariance; 95% CI 0.8 to 3.0) was observed between glaucomatous eyes that showed visual field deterioration and glaucomatous eyes that did not progress. A significant difference of 16.8% (SD 4.6%) in the mean percentage of IOP variation was also observed between the two groups (p<0.001, analysis of covariance; 95% CI 7.7 to 26.0).

Conclusions: Mean IOP peak and percentage of IOP variation during water drinking test were significantly higher in patients with visual field progression compared with patients who did not progress.


Abbreviations: CPSD, corrected pattern standard deviation; IOP, intraocular pressure

Keywords: intraocular pressure; diurnal tension curve; glaucoma; visual field progression; water drinking test




This article has been cited by other articles:


Home page
J. Am. Coll. Nutr.Home page
F. Manz
Hydration and Disease
J. Am. Coll. Nutr., October 1, 2007; 26(suppl_5): 535S - 541S.
[Abstract] [Full Text] [PDF]


Home page
Arch OphthalmolHome page
D. B. Henson and S. Shambhu
Relative Risk of Progressive Glaucomatous Visual Field Loss in Patients Enrolled and Not Enrolled in a Prospective Longitudinal Study
Arch Ophthalmol, October 1, 2006; 124(10): 1405 - 1408.
[Abstract] [Full Text] [PDF]