BJO

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

British Journal of Ophthalmology 2005;89:1438-1441; doi:10.1136/bjo.2005.071761
Copyright © 2005 by the BMJ Publishing Group Ltd.

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Adams, W E
Right arrow Articles by Clarke, M P
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Adams, W E
Right arrow Articles by Clarke, M P

SCIENTIFIC REPORT

Frisby Davis distance stereoacuity values in visually normal children

W E Adams1, S Hrisos2, S Richardson1, H Davis4, J P Frisby5, M P Clarke3

1 Department of Ophthalmology, Royal Victoria Infirmary, Newcastle upon Tyne, UK
2 Research Associate, Centre for Health Services Research, University of Newcastle upon Tyne, Newcastle upon Tyne, UK
3 Department of Ophthalmology, University of Newcastle upon Tyne, Newcastle upon Tyne, UK
4 Academic Unit of Ophthalmology and Orthoptics, University of Sheffield, Sheffield, UK
5 Department of Psychology, University of Sheffield, Sheffield, UK

Correspondence to:
Correspondence to:
Wendy E Adams
Royal Victoria Infirmary, Queen Victoria Road, Newcastle upon Tyne NE1 4LP, UK; wendy_stoer{at}yahoo.com


ABSTRACT
Aims: To establish the range of normal distance stereoacuity in young children using the Frisby Davis distance stereotest (FD2).

Methods: Children passing preschool vision screening assessments underwent measurement of distance stereoacuity with the FD2 using a standard testing protocol.

Results: 59 visually normal children aged between 36 months and 68 months were recruited to this study. All 59 were able to understand the test requirements and were examined with the FD2 stereotest. Four (6.8%) had no measurable stereoacuity; 13 (24%) had stereoacuity measurable only at a 3 metre testing distance (mean 92.3 seconds of arc; SD 52.6). These children were significantly younger than the remaining 42 (76%) who demonstrated a stereoacuity response at a 6 metre testing distance (mean 29.6 seconds of arc; SD 13.1, p = 0.008).

Conclusion: The FD2 stereotest enables the measurement of distance stereoacuity in young children. There appears to be a maturational effect with distance stereoacuity improving between 36 months and 68 months. The data on age related normal values will provide a baseline from which to compare outcomes in clinical populations.


Abbreviations: FD2, Frisby Davis distance stereotest

Keywords: distance stereoacuity; Frisby Davis distance stereopsis test; children




This article has been cited by other articles:


Home page
Br. J. Ophthalmol.Home page
S W Hong and S C Park
Development of distant stereoacuity in visually normal children as measured by the Frisby-Davis distance stereotest
Br. J. Ophthalmol., September 1, 2008; 92(9): 1186 - 1189.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Ophthalmol.Home page
S R Hatt, H Haggerty, D Buck, W Adams, N P Strong, and M P Clarke
Distance stereoacuity in intermittent exotropia
Br. J. Ophthalmol., February 1, 2007; 91(2): 219 - 221.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2005 by the BMJ Publishing Group Ltd.