BJO

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

British Journal of Ophthalmology 2005;89:1569-1571; doi:10.1136/bjo.2005.080655
Copyright © 2005 by the BMJ Publishing Group Ltd.

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Siddiqui, M A R
Right arrow Articles by Neville, S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Siddiqui, M A R
Right arrow Articles by Neville, S

SCIENTIFIC REPORT

Effect of cataract extraction on frequency doubling technology perimetry in patients with glaucoma

M A R Siddiqui, A Azuara-Blanco, S Neville

Department of Ophthalmology, NHS Grampian, University of Aberdeen AB25 2ZN, UK

Correspondence to:
Correspondence to:
Augusto Azuara-Blanco
PhD, FRCS(Ed), The Eye Clinic, Aberdeen Royal Infirmary, Aberdeen AB25 2ZN, UK; aazblanco{at}aol.com


ABSTRACT
Aim: To evaluate the effect of cataract surgery on frequency doubling technology (FDT) perimetry in patients with co-existing cataract and glaucoma.

Methods: In this consecutive prospective cohort study 27 patients with open angle glaucoma scheduled for cataract extraction alone or combined with trabeculectomy were enrolled. All patients underwent FDT threshold C-20 visual fields within 3 months before and 3 months after surgery. Changes in mean deviation (MD) and pattern standard deviation (PSD) were evaluated. Additionally, changes in best corrected logMAR visual acuity (VA), intraocular pressure (IOP), and number of glaucoma medications were also studied.

Results: 22 patients completed the study. VA improved after surgery, from 0.47 (SD 0.19) to 0.12 (0.17) (p<0.001). The visual indexes changed after cataract extraction: MD improved (from –10.9 (SD 4.6) dB to –7.0 (4.6) dB; p<0.001) while PSD worsened (from 7.1 (SD 3.5) dB to 8.5 (3.8) dB; p = 0.001).

Conclusion: In patients with co-existing cataract and glaucoma, examined with FDT, MD improved and PSD worsened after cataract surgery. Global indexes of FDT should be interpreted with caution in patients with glaucoma and cataracts.


Abbreviations: FDT, frequency doubling technology; IOP, intraocular pressure; MD, mean deviation; PSD, pattern standard deviation; SWAP, short wavelength automated perimetry; VA, visual acuity; VF, visual fields

Keywords: glaucoma; frequency doubling technology; visual fields; cataract







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2005 by the BMJ Publishing Group Ltd.