BJO

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

British Journal of Ophthalmology 2008;92:143-146; doi:10.1136/bjo.2007.125435
Copyright © 2008 by the BMJ Publishing Group Ltd.

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kaiserman, I
Right arrow Articles by Rootman, D S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kaiserman, I
Right arrow Articles by Rootman, D S

SURGICAL TECHNIQUES

Half-top-hat—a new wound configuration for penetrating keratoplasty

I Kaiserman, I Bahar, D S Rootman

Department of Ophthalmology, Toronto Western Hospital, University of Toronto, Toronto, Ontario, Canada

Correspondence to:
I Kaiserman, Department of Ophthalmology, Toronto Western Hospital, 399 Bathurst St, Toronto, Ontario, Canada M5T2S8; igor{at}dr-kaiserman.com


ABSTRACT
Aims: To describe a new, simpler method of achieving the advantages of a lamellar wound configuration in penetrating keratoplasty (PKP)—the half-top-hat (HTH) configuration.

Methods: The donor corneal button was prepared in a top-hat configuration, as previously described. It consisted of a central, full-thickness part, 7–8 mm in diameter, surrounded by a peripheral lamellar wing of deep stroma and endothelium that was 0.5 mm in width (wing diameter 8–9 mm). The recipient bed was prepared by a straight full thickness trephination with a suction trephine. The donor button was positioned by sliding the peripheral wing under the recipient bed. Sixteen 10-0 interrupted sutures and a single continuous 16-bite 11-0 nylon sutures were placed. The interrupted sutures were passed so as to go through the wing, in order to ensure a good apposition of the wing to the inner corneal surface of the recipient. Anterior segment optical coherence tomography (Visante OCT) was used to image the position and alignment of the corneal graft postoperatively.

Results: Ten eyes of 10 patients (mean (SD) age: 73.7 (11.4) years, 7 females) underwent HTH PKP. The donor lenticule diameter was 7.7 (0.3) mm (wing diameter 8.7 (0.3) mm). The mean follow-up time was 2.4 (0.7) months. The last median visual acuity was 20/200 (range 20/80-counting fingers), and the last IOP was 18.2 (8.8) mm Hg. No major intraoperative complications were noted. No postoperative events of graft rejection were documented. No anterior surface misalignment was noted either clinically or by OCT. One patient had a rise in IOP postoperatively.

Conclusions: Half-top-hat wound configuration is a valid alternative in penetrating keratoplasty. Its advantages include better apposition of donor and recipient corneas, improved tectonic strength to prevent graft dehiscence, the possibility of early sutures removal and being a simpler procedure to perform.



FOOTNOTES
Funding: IK is a recipient of fellowship from the American Physicians Fellowship for Medicine in Israel.

Competing interests: All authors declare no financial interests.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2008 by the BMJ Publishing Group Ltd.